Radon Test Overview

For complete information on Radon Testing and Mitigation, please visit the PADEP Radon website.

 

Radon Test Prices

  • $150 Add to Base Price if Radon Test added to Home Inspection
  • $25 Add to Radon Price if the test is set before or after Home Inspection
  • $175 for Radon Test without Home Inspection

Radon Test using E-Perm System - Testing will be performed by VBInspect.com, a PA certified Radon testing firm and Individual Certification ID #3184. For more information about Radon and Radon testing, please visit the PADEP Radon website or the EPA's Radon Page. Please be advised that the radon test will require closed house conditions for 12 hours prior to placement of the test. Closed house conditions will also be required during the test (2-5 days). Click this link for the Radon Placement Requirements. You or your agent should inform the seller about the Radon test.

 

Radon Test using E-Perm System

For more information on the E-Perm System, please visit the Radelect website: http://www.radelec.com/

The Pennsylvania Department of Environmental Protection (DEP) recommends testing the lowest livable area of the building and considers the basement, if any, to be the lowest livable area if it can be used as a living area without major structural changes. For real estate transactions, this is true even if the basement is not currently renovated into a finished living space because the buyer may renovate and use the basement as a living space. Naturally, basements with ground floors or low ceilings would need major structural changes and, therefore, would not be considered the lowest livable area.

 

Closed House Conditions

Please be advised that the radon test will require closed house conditions for 12 hours prior to placement of the test. Closed house conditions will also be required during the test (2-5 days).  If this is for a real estate transaction, you or your agent should inform the seller about the Radon test.

If a radon test is placed for less than four days, all doors and windows must be closed, except for normal entrance and exiting, and all fans and other external/internal ventilation systems, except the furnace, must not be operating for at least 12 hours prior to the test and during the entire testing period. If closed house conditions have not been maintained for 12 hours prior to placement of the test, a 4 day (or more) test is required.

Short-term tests lasting less than four days should not be conducted during severe storms or periods of high winds. In other words, if there are high winds during a 2 day test, the test must be extended to a 4 day test.

Placement: All radon testing devices must be placed at least:

  • 20 inches off the floor
  • 4 inches from other objects
  • 1 foot from external walls
  • 3 feet from windows or other potential openings in the exterior walls
  • at least 48 hours.

Notice: The Radon Certification Act requires that anyone who provides any radon-related service or product to the general public must be certified by the Pennsylvania Department of Environmental Resources. You are entitled to evidence of certification from any person who provides such services or products. You are also entitled to a price list for services or products offered. All radon measurement data will be sent to the Department as required in the Act and will be kept confidential. If you have any questions, comments or complaints, concerning persons who provide radon-related services, please contact the Department at the Bureau of Radiation Protection, Pa. Department of Environmental Protection, P.O. Box 8469, Harrisburg, PA. 17105-8469, (717) 783-3594 or (800) 237-2366

 

Radon placement/pick-up

The home inspector will only visit the property one time for the inspection and often the radon canisters will be picked up by a non-inspector employee.  Radon pick-ups take approximately 5-10 minutes and we are unable to inspect or evaluate any other component of the property during that time.